CDI Save Status
Saved
Waiting for CDI sync
Tap to show save button
Connect to the CDI to track save state and store changes.
Save to CDI
Kill Engine
System State
Connection
Connected to CDI
Dashboard
Launch
Rev Limit
Maps
RPM
Wi-Fi
System Details
Active Map
Launch RPM
6000
Launch target in use
Rev Limit
10500
Configured limiter threshold
System Summary
Source
CDI
Connection
Online
Auto Sync
Running
Edit Flow
Live + safe queue
Current Operating Zone
Live RPM
--
Active Zone
--
Blend
--
Est. Advance
--
Recent Changes
No tune changes yet in this browser session.
Launch Control
Launch RPM Mode
Same launch RPM for all maps
Different launch RPM for each map
All maps use one launch RPM value.
Launch RPM
6000 RPM
Editing shared launch RPM for all maps.
Show Advanced
Launch Control Behavior
Progressive retard + cut
Keep 1 / Drop N
Uses the current progressive launch strategy with retard and increasing cut.
Launch Pattern Drop Count
Drop 1
Used only when Launch Control Behavior is set to Keep 1 / Drop N.
Launch Pattern Extra Retard Deg
Applied only on kept sparks when Launch Control Behavior is Keep 1 / Drop N.
Rev Limiter
Rev Limit RPM
10500 RPM
Show Advanced
Rev Limiter Strategy
Hard cut
Hard cut + recovery control
Keep 1 / Drop N
Soft fixed angle
Soft fixed angle + max time + hard cut
Soft progressive retard
Soft progressive retard + max time + hard cut
Modulated percent cut
Choose how the limiter behaves when RPM approaches or crosses the limit.
Rev Pattern Drop Count
Drop 6
Used only when Rev Limiter Strategy is Keep 1 / Drop N.
Rev Soft Span RPM
How far below the hard limit the soft limiter starts.
Rev Soft Hysteresis RPM
How far RPM must fall below the soft start before leaving the soft zone.
Rev Soft Fixed Angle Deg
Used by soft fixed-angle modes.
Rev Soft Max Retard Deg
Used by soft progressive-retard modes.
Rev Soft Max Time ms
Used only by soft max-time limiter modes.
Rev Hard Hysteresis RPM
How far RPM must fall below the hard limit before cut is allowed to release.
Rev Min Cut Time ms
Used by hard cut + recovery control and all soft+hard strategies.
Rev Recovery Good Pulses
How many good pulses below the release RPM are required before hard cut is released.
Rev Min Cut %
Used only by the modulated percent-cut strategy.
Rev Max Cut %
Used only by the modulated percent-cut strategy.
Pulser Angle Deg
45°
Only adjust this if the engine does not run correctly. Normal tuning should leave this alone.
Active Map
Tap a map to make it active immediately.
Map Curve
Live RPM
--
Active Zone
--
Est. Advance
--
Map Tools
Fast shape edits for the active map without typing every bin by hand.
Copy another map into the active map
Mild
Performance
Race
Instant Torque
Extreme
Branch from an existing map and fine tune from there.
Copy Into Active
Offset -1°
Offset +1°
Smooth Active
Reset Active
Preset Library
Save complete tune snapshots in your browser, add notes, and reload them later.
Saved Presets
No preset selected.
Preset Name
Preset Notes
Save Current Preset
Load Selected Preset
Delete Selected
Active Map Summary
Lowest Advance
--
Highest Advance
--
Average Advance
--
Launch For Active Map
6000
Mild Map Active Editor
49 bins | 250 RPM steps | 0.1°
Live RPM
--
Wi-Fi Setup
Wi-Fi SSID
1 to 32 characters.
Wi-Fi Password
Leave blank for an open AP, or use at least 8 characters.
Confirm Wi-Fi Password
ESP Sleep Mode
Sleep after 1 minute
Sleep after 2 minutes
Sleep after 5 minutes
Never sleep
ESP hotspot sleep is handled locally by the ESP32-C3.
Save Wi-Fi
Clear Saved Wi-Fi
Reboot ESP
Hotspot Summary
Configured SSID
1ZPerformance
Password State
set
Current IP
192.168.4.1
Connected Stations
1
AP Started
started
ESP Sleep Mode
2 minutes
Last AP Event
running
Connection & Sync
Config Ready
true
Current Source
Live CDI config
Auto Sync
Running
Save State
idle
Last UI Message
Waiting for CDI config
RP Serial & RPM
Live RPM
--
Live Stream
on
Last RP Command
SIM LOOP
Last RP Reply
OK
Tune Snapshot
Selected Map
Mild
Launch Mode
shared
Launch RPM
6000
Launch Behavior
progressive
Launch Drop Count
1
Launch Pattern Retard
0°
Rev Limit
10500
Rev Behavior
pattern
Rev Drop Count
6
Rev Soft Span
250
Rev Soft Max Time
300
Rev Cut % Range
20-85
Pulser Angle
45°
Access Point Status
Wi-Fi SSID
1ZPerformance
Wi-Fi Password
set
SoftAP IP
192.168.4.1
Stations
1
AP Started
started
ESP Sleep Mode
2 minutes
Last AP Event
running